Uploaded image for project: 'FHIR Specification Feedback'
  1. FHIR Specification Feedback
  2. FHIR-19563

STU3 DeviceRequest base profile defines incorrect ValueSet reference for intent element binding

    XMLWordPrintableJSON

Details

    • Icon: Change Request Change Request
    • Resolution: Persuasive
    • Icon: Medium Medium
    • FHIR Core (FHIR)
    • STU3
    • Orders & Observations
    • DeviceRequest (was DeviceUseRequest)
    • Hide

      Proposed motion to find persuasive. It appears this is already fixed.

      Show
      Proposed motion to find persuasive. It appears this is already fixed.
    • Rob Hausam/Hans Buitendijk: 12-0-1
    • Correction
    • Non-substantive
    • Yes
    • R5

    Description

      The STU3 (v3.0.1) DeviceRequest base profile incorrectly defines the intent element's binding ValueSet reference as "http://build.fhir.org/valueset-request-intent.html". The correct reference is "http://hl7.org/fhir/ValueSet/request-intent".

      I went back to the FHIR STU3 v3.0.1 profile and confirmed it's in the DeviceRequest XML Excel spreadsheet under the Bindings tab for the RequestIntent binding name.

      Per Lloyd's recommendation, this should be manually corrected in the FHIR STU3 (v3.0.1) validation package file and updated on the FHIR STU3 (v3.0.1) specification's downloads page.